Syngas Engine Generator Biomass Gasifier 500kw
Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation. The generator is desirable for industrial power solution.
MAIN SPECIFICATIONS OF GAS GENERATOR SET
Model |
1000GF-NK |
|
Gas Engine Model |
H16V190ZLZ-2 |
Rated power |
1000kW/1250KVA |
|
Alternator |
Siemens Series |
Rated voltage |
400 V |
|
Starting method |
24V DC electric start |
Rated speed |
1000rpm |
|
Voltage regulation |
Automatic |
Rated frequency |
50Hz |
|
Cooling Mode |
Close type water cool |
Rated current |
1805A |
|
Heat Consumption |
£ 9500kJ/kWh |
Power factor |
0.8 Lagging |
|
Dimension (mm) |
5998×2516×2540mm |
Control mode |
Electric control |
|
Net Weight (kg) |
21000 |
MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR
Voltage |
Stabilized regulation |
Instantaneous regulation |
Recovery time |
Fluctuation |
±2.5% |
+15% |
2 S |
1% |
Frequency |
Stabilized regulation |
Instantaneous regulation |
Recovery time |
Fluctuation |
0-5% adjustable |
≤±5% |
< 7 S |
1% |
MAIN SPECIFICATIONS OF GAS ENGINE
Model |
H16V190ZLZ-2 |
Rated power |
1000kW/1250KVA |
Number and layout of cylinders: |
16-cylinders, V-type, 60° included angle |
Type |
Four stroke, water cooled, turbocharged and after cooled, direct injection |
Ignition type |
Spark plug ignition |
Intake gas pressure required |
7-9kPa |
Bore´Stroke |
190´215 mm |
Speed Governor |
Woodward Electric governor |
Oil consumption |
£ 1.0g/kWh |
Total lubricating oil capacity (Liters) |
460L |
Exhaust temperature (before turbine) |
£ 680 °C |
Heavy overhauling period |
56,000h |
MAIN SPECIFICATIONS OF ALTERNATOR
Alternator model |
Exciting model |
Insulation class |
Connection |
Cooling |
Structure type |
1FC5456-6TA42 (SIEMENS) |
Brushless |
Class F |
3-phase, 4-wire |
Air cooled |
AVR and reactive droop regulator assembled in alternator |
(Kindly Noted: data shown in above table tested under standard working condition: 25 Dec C, atmospheric pressure 100kPa, relative humidity 30%, altitude <1000m.)
CONTROL PANEL
Control panel is panel type, vertical structure, model is GPL1000. Control panel is equipped with meters showing various parameters of operating status, automatic air switch and timer. All of the electric cells possess three-proof functions.
The Generator possesses the following automatic monitoring and protective functions:
A) Audio or visual alarm for:
- High oil and water temperature
- Low oil pressure
- Over current
- Short circuit
- Over-speed
- Reverse power
B) Shut-off for:
- Low oil pressure
- Over-speed
- Short circuit
- Over-speed
- Reverse power
C) Trip-off for:
- Over-current
- Short circuit
- Reverse power
The generator can not only supply power directly to load but also can be paralleled running.
OPTIONAL DEVICE
Steel Soundproof Container (sound attenuated canopy)
CHP/ Cogeneration/CCHP Trigeneration
ATS and Synchronization Parallelling Panel
Oil and Water Heater
Syngas Engine Generator Biomass Gasifier 500kw