| Model | 2000GF-T | Gas Engine Model | L20V190ZLT-1 | |
| Rated power | 2000kW/2500KVA | Alternator | Siemens Series | |
| Rated voltage | 10.5k V | Starting method | 24V DC electric start | |
| Rated speed | 1000rpm | Voltage regulation | Automatic | |
| Rated frequency | 50Hz | Cooling Mode | Close type water cool | |
| Rated current | 137.5A | Heat Consumption | 9200kJ/kWh | |
| Power factor | 0.8 Lagging | Dimension (mm) | 9583x2180x2540mm | |
| Control mode | Electric control | Net Weight (kg) | 28000 |
| Voltage | |||
| Stabilized regulation | Instantaneous regulation | Recovery time | Fluctuation |
| ±2.5% | +20% - 15% | 1.5S | 0.5% |
| Frequency | |||
| Stabilized regulation | Instantaneous regulation | Recovery time | Fluctuation |
| 0-5% adjustable | +10%,-10% | < 7 S | 0.5% |
| Model | L20V190ZLT-1 |
| Rated power | 2000kW (2500KVA) |
| Number and layout of cylinders: | 20-cylinders, V-type, 60° included angle |
| Type | Four strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor |
| Ignition type | Spark plug ignition |
| Intake gas pressure required | 100-400 kPa before gas pressure regulator |
| Bore´Stroke | 190´255 mm |
| Speed Governor | (Woodward) Electric governor |
| Oil consumption | £ 0.8g/kWh |
| Total lubricating oil capacity (Liters) | 600L |
| Exhaust temperature (before turbine) | £ 680 °C |
| Heavy overhauling period | 36,000h |
| Alternator model | Exciting model | Insulation class | Connection | Cooling | Structure type |
| 1FC series (SIEMENS) |