• 1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
  • 1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
  • 1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
  • 1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
  • 1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
  • 1MW 2MW 5MW Dual Fuel Genset Gas Power Plant

1MW 2MW 5MW Dual Fuel Genset Gas Power Plant

After-sales Service: O&M Oversea
Warranty: O&M Oversea
Output Type: AC Three Phase
Transport Package: Wood Cases Packing
Specification: 2000GF-DT
Trademark: Jichai
Gold Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
1000GF-DS
Origin
China
HS Code
85022000

Product Description

1MW 2MW 5MW 10MW Diesel+Gas Dual Fuel Genset Gas power plant/LNG CNG LFG MSW gas generator 500kw 700kw 800kw
1MW 2MW 5MW Dual Fuel Genset Gas Power Plant1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation. The generator is desirable for industrial power solution.
 
Item Unit Specification
Model   DG1000GF1-2B
Rated power kW 1000
Rated rev. rpm 500
Rated voltage V 400
Rated current A 1804
Frequency Hz 50Hz
Power factor   0.8 (lagging)
Phase   3-phase 4wire
Voltage fluctuation rate % ±1
Frequency (rev.)  fluctuation rate % ±0.5
Stable voltage regulating rate % ±2.5
Stable frequency (rev.) regulating rate % 5
Transient voltage regulating rate % ±20~-15
Stabilizing time s 5
Voltage regulating method   Auto digital AVR ABB or Basler
Speed Governor    comAp Econ4+ WoodwardUGA
Frequency regulating method   Auto/Manual
Lubricating method   Pressure lubricating
Lubricating oil type   SAE 40 with TBN30
Starting mode   Compressed air via rotary valve
Fuel   Diesel+Natural Gas
Generator sets cooling   Close circuit of fresh cooling water
Alternator cooling   air
Insulation   (F)
IP   IP23
Fuel comsuption g/kWh Fuel 212(ISO3046-1)
Fual and gas ratio   3:7(30% diesel,70% gas)
Lube oil comsuption g/kWh 0.8
Idle speed rpm 240
Excation type   Brushless self-excation
Connection   coulping
Painting   According to client
Installation   Command base with rubber
Dimension mm 8550X2735X3250
Weight T 42500
1MW 2MW 5MW Dual Fuel Genset Gas Power Plant1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
Diesel engine data
Item Unit Specification
Model   DF6300
Number of cylinders Pc 6
Arrangement of cylinders   In Line
Bore mm 300
Stroke  mm 380
Type   4-stroke, direct injection, turbocharger, after cooler
Exhaust temp. ºC 370
Back pressure kPa 3
Speed rpm 500
Fuel comsuption g/kWh 192(ISO3046-1)
Mean effective pressure at rated power & speed Bar 1.62
Mean piston speed m/s 6.33
Compression ratio   13:1
Rated power under ISO Conditions at engine crankshaft   1103kW/500RPM
1h capacity   1213kW/500rpm
Rotation seen from flywheel   Clockwise
Overhaul period h 18000
Life year 25
1MW 2MW 5MW Dual Fuel Genset Gas Power Plant1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
Under the following limiting ambient conditions:
Air temp. at turbocharger inlet      45 deg. C
Water temp. at charge air cooler inlet    32 deg. C
Deration to power applicable for engine 0 %( nil)
Beyond the abovementioned limiting conditions, deration to power as per ISO 3046 will be applicable.
Rated Power under site conditions mentioned above:
  1MW 2MW 5MW Dual Fuel Genset Gas Power Plant1MW 2MW 5MW Dual Fuel Genset Gas Power Plant                                      
Maximum continuous rating (MCR)     1200 HP
at engine crankshaft
The engine should be capable of accepting a sudden load as per the guidelines in ISO-8528-5-1993(e). As per this standard, the maximum sudden load increase stages are

               Baseload %     sudden load   increase to %
--------------------------------------------------------------------------------
1st Stage       0%          40                40%
2nd Stage       40%         30              70%
3rd Stage       70%         20              90%
4th Stage       90%         10              100%
--------------------------------------------------------------------------------
During each of the above-mentioned stages of sudden loading, the transient speed drop will be restricted to a maximum value of 10% of the rated speed.  

Alternator data
Alternator is self-excited, brush less type in two bearing construction with single shaft extension and IP 23 enclosure. Alternator is fitted with bearing temperature detectors.
 
Rated KVA 1250 KVA
Power factor 0.8 lag
Rated Alternator output at site 1000 KW
Duty Continuous
Rated speed 500 RPM
Output voltage 400 V
Efficiency at 100% load and 0.8 PF100% 94.5 %
Direction of rotation Clockwise
Number of poles 12
Rated frequency 50 Hz
Over-speed 20% for 2 minutes
Overload capacity and duration 10%, for max. 1 hr in every 12 hrs
Insulation class F
Enclosure IP 23
Temp. Rise F
Excitation and AVR type Brush-less, AVR
Connection 3-phase 4-wire

Gas protection system
The DG set is equipped with gas leakage alarm monitoring equipment, which respectively monitors the gas stock in the fresh air inlet main pipe, the gas proportion in the exhaust position of the crankcase breathing apparatus, and the concentration of combustible gas in the main building. When the gas concentration exceeds the set value, the dual-fuel system will quit operation.
When the exhaust temperature is too high, the dual fuel system will automatically and quickly switch to diesel operation mode
When the DG set fault, the gas quick break valve will close automatically
High/Low gas pressure alarm
1MW 2MW 5MW Dual Fuel Genset Gas Power Plant1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
OPTIONAL DEVICE

  Steel Soundproof Container (sound attenuated canopy)
 CHP/ Cogeneration/CCHP Trigeneration
1MW 2MW 5MW Dual Fuel Genset Gas Power Plant1MW 2MW 5MW Dual Fuel Genset Gas Power Plant
ATS and Synchronization Parallelling Panel
  Oil and Water Heater

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Trading Company
Number of Employees
71
Year of Establishment
2006-09-19