Customization: | Available |
---|---|
Voltage: | 380V |
Generating Methods: | Gas Engine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | 1200GF-T | Gas Engine Model | H16V190ZLT-2 | |
Rated power | 1200kW/1500KVA | Alternator | Siemens Series | |
Rated voltage | 400 V | Starting method | 24V DC electric start | |
Rated speed | 1000rpm | Voltage regulation | Automatic | |
Rated frequency | 50Hz | Cooling Mode | Close type water cool | |
Rated current | 2164A | Heat Consumption | 10200kJ/kWh | |
Power factor | 0.8 Lagging | Dimension (mm) | 6583x2180x2540mm | |
Control mode | Electric control | Net Weight (kg) | 24000 |
Voltage | |||
Stabilized regulation | Instantaneous regulation | Recovery time | Fluctuation |
±2.5% | +20% - 15% | 1.5S | 0.5% |
Frequency | |||
Stabilized regulation | Instantaneous regulation | Recovery time | Fluctuation |
0-5% adjustable | +10%,-10% | < 7 S | 0.5% |
Model | H16V190ZLT-2 |
Rated power | 1320kW (1650KVA) |
Number and layout of cylinders: | 16-cylinders, V-type, 60° included angle |
Type | Four strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor |
Ignition type | Spark plug ignition |
Intake gas pressure required | 100-400 kPa before gas pressure regulator |
Bore´Stroke | 190´215 mm |
Speed Governor | (Woodward) EGS-02 Electric governor |
Oil consumption | £ 0.8g/kWh |
Total lubricating oil capacity (Liters) | 460L |
Exhaust temperature (before turbine) | £ 680 °C |
Heavy overhauling period | 36,000h |
Alternator model | Exciting model | Insulation class | Connection | Cooling | Structure type |
1FC6564-6LA42 (SIEMENS) | Brushless | Class F | 3-phase, 4-wire | Air cooled | AVR and reactive droop regulator assembled in alternator |