• 400kw CNG Pipeline Natural Gas Powered Generator
  • 400kw CNG Pipeline Natural Gas Powered Generator
  • 400kw CNG Pipeline Natural Gas Powered Generator
  • 400kw CNG Pipeline Natural Gas Powered Generator
  • 400kw CNG Pipeline Natural Gas Powered Generator
  • 400kw CNG Pipeline Natural Gas Powered Generator

400kw CNG Pipeline Natural Gas Powered Generator

After-sales Service: O&M Oversea
Warranty: 1year
Output Type: AC Three Phase
Gas Source: Natural Gas
Certification: CE, ISO, CCC
Power: 500kw
Gold Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
500GF-N
Standard
Standard
Rpm
1000
Control
Comap
Transport Package
Wood Cases Packing
Specification
700GF-N
Trademark
Jichai
Origin
China
HS Code
85022000

Product Description

400kw CNG Pipeline Natural Gas Powered Generator 


400kw CNG Pipeline Natural Gas Powered Generator
Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation. The generator is desirable for industrial power solution.
MAIN SPECIFICATIONS OF GAS GENERATOR SET
Model 700GF-T   Gas Engine Model M12V190ZL
Rated power 700kW/875KVA   Alternator Siemens Series
Rated voltage 400 V   Starting method 24V DC electric start
Rated speed 1000rpm   Voltage regulation Automatic
Rated frequency 50Hz   Cooling Mode Close type water cool
Rated current 902A   Heat Consumption £ 9800kJ/kWh
Power factor 0.8 Lagging   Dimension (mm) 5120x2040x2219mm
Control mode Electric control   Net Weight (kg) 14500
400kw CNG Pipeline Natural Gas Powered Generator
MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR
Voltage
Stabilized regulation Instantaneous regulation Recovery time Fluctuation
±2.5% +20% 2 S 1%
Frequency
Stabilized regulation Instantaneous regulation Recovery time Fluctuation
0-5% adjustable +10%,-12% < 10 S 1%

MAIN SPECIFICATIONS OF GAS ENGINE
Model M12V190ZL
Rated power 700kW/875KVA
Number and layout of cylinders: 12-cylinders, V-type, 60° included angle
Type Four strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor
Ignition type Spark plug ignition
Intake gas pressure required 7-9kPa
Bore´Stroke 190´210 mm
Speed Governor (Woodward) EGS-02 Electric governor
Oil consumption £ 0.6g/kWh
Total lubricating oil capacity (Liters) 200L
Exhaust temperature (before turbine) £ 680 °C
Heavy overhauling period 36,000h
MAIN SPECIFICATIONS OF ALTERNATOR
 
Alternator model Exciting model Insulation class Connection Cooling Structure type
1FC5456-6TA42 (SIEMENS) Brushless Class F 3-phase, 4-wire Air cooled AVR and reactive droop regulator assembled in alternator
 
(Kindly Noted: data shown in above table tested under standard working condition: 25 Dec C, atmospheric pressure 100kPa, relative humidity 30%, altitude <1000m.)

Requirments for natural gas
1.Methane should be at least 95%
2.The natural gas temperature should be between 0-60 ºC
3. No inpurity should be in the gas. Water in the gas should be less than 20g/Nm3.
4. Heat value should be at least 8500kcal/m3, if less than this value, the power of the engine will be declined.
5. Gas pressure should be 3-100KPa, if the pressure is less than 3KPa, booster fan is necessary.
6.The gas should be dehydrated and desulfurated. Make sure that there is no liquid in the gas. H2S<200mg/Nm3

400kw CNG Pipeline Natural Gas Powered Generator400kw CNG Pipeline Natural Gas Powered Generator400kw CNG Pipeline Natural Gas Powered Generator
CONTROL PANEL
Control panel is panel type, vertical structure, model is GPL700. Control panel is equipped with meters showing various parameters of operating status, automatic air switch and timer. All of the electric cells possess three-proof functions.

The Generator possesses the following automatic monitoring and protective functions:

A) Audio or visual alarm for:
-   High oil and water temperature
-   Low oil pressure
-   Over current
-   Short circuit
-   Over-speed
-   Reverse power
B) Shut-off for:
-   Low oil pressure
-   Over-speed
-   Short circuit
-   Over-speed
-   Reverse power
C) Trip-off for:
-   Over-current
-   Short circuit
-   Reverse power
The generator can not only supply power directly to load but also can be paralleled running.
400kw CNG Pipeline Natural Gas Powered Generator400kw CNG Pipeline Natural Gas Powered Generator400kw CNG Pipeline Natural Gas Powered Generator400kw CNG Pipeline Natural Gas Powered Generator
OPTIONAL DEVICE
Steel Soundproof Container (sound attenuated canopy)
400kw CNG Pipeline Natural Gas Powered Generator400kw CNG Pipeline Natural Gas Powered Generator400kw CNG Pipeline Natural Gas Powered Generator
CHP/ Cogeneration/CCHP Trigeneration
ATS and Synchronization Parallelling Panel
Oil and Water Heater

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Trading Company
Number of Employees
71
Year of Establishment
2006-09-19